©2018 Medtronic. All Rights Reserved. 02/2018 – US170997 – [WF#1960968]
VALLEYLAB™ FX8
ENERGY PLATFORM
REFERENCES
SOFT COAG
The “soft coag” mode desiccates tissue at a relatively slower rate than fulguration, with deeper thermal penetration.4 It is typically performed with a ball
electrode or the flat surface of the spatula electrode.
The soft coag mode introduces new possibilities
over a variety of procedures, including:
Soft coag with irrigation
Soft coag with suction
Plus, it can be used to stop venous oozing.
Soft Coag with Irrigation
Soft Coag with Suction
REFERENCES
1. Based on internal report #RE00117085 Rev A, Monopolar Thermal Effect, Drag and Power for Valleylab™ FX8 and Valleylab™ FT10 energy platforms compared to the ForceFX™ MegaPower™*, Conmed 5000™*, and the Erbe VIO™* D energy platforms, October 2017.
2. Based in internal report #RE00126471_A, VLFX8GEN Control System Resolution. November 2017.
3. Based on internal memo #R00027952, monopolar and bipolar power control data. October 2015.
4. Based on internal report #RE00058763 Rev A, Verification of monopolar thermal effect for Valleylab™ FX8 generator. June 2017
5. Based on internal report #RE00105221, Comparison testing of the Valleylab™ FT10 and ForceTriad™ generators. The Valleylab™ FT10 energy platform has identical power curves and equivalent power delivery for shared modes to the Valleylab™ FX8 energy platform. July 2017.
6. Based on internal test report #RE00035369, Verification of Captain Hook (LF5637/LF5644) devices: monopolar thermal effect evaluation - 04/2016.
7. Based on internal report #RE0068753, A Quantitative Comparison to Conventional Monopolar Electrosurgery, L-Hook Monopolar Drag Force Measurements. March 2017
8. Based on internal test report #RE00005401, Product validation of Valleylab™ FT10 energy platform surgeon and nurse evaluation in simulated use: 32 surgeons interviewed. January 27 to 30, 2015 and Feb. 24 to 27, 2015.
SOFT COAG
VALLEYLAB™ FX8
ENERGY PLATFORM
The “soft coag” mode desiccates tissue at a relatively slower rate than fulguration, with deeper thermal penetration.4 It is typically performed with a ball electrode or the flat surface of the spatula electrode.
The soft coag mode introduces new possibilities
over a variety of procedures, including:
Soft coag with irrigation
Soft coag with suction
Plus, it can be used to stop venous oozing.
Soft Coag with Suction
Soft Coag with Irrigation
REFERENCES
1 Based on internal test report #RE00005503, Verification of the Valleylab™ FX8 generator in an acute hemostasis porcine study. January 2015.
2 Based on internal test report #RE00004823 Rev A, Verification – report – tag-on animal lab - LigaSure™ preclinical lymphatic sealing evaluation of the Valleylab™ FX8. March 2015.
3 Based on internal test report #R0064459 Rev B, Verification – report – LigaSure™ pulmonary bench pressure evaluation of the Valleylab™ FX8. March 2015.
4 Based on internal test report #R0064457 Rev A, Verification – report – LigaSure™ renal bench burst pressure evaluation of the Valleylab™ FX8. April 2015.
5 Based on internal test report #RE00005506, Verification of the Valleylab™ FX8 generator in a chronic hemostasis porcine study. February 2015.
6 Based on internal test report #R0064462 Rev B, Verification – report – LigaSure™ thermal profile Valleylab™ FX8. February 2015.
7 Based on internal test report #RE00025819 Rev A, LigaSure™ data sources for VLFX8 white papers: bench testing model used to evaluate sealing time. September 2015.
8 Based on the Valleylab™ FX8 service manual: part number 1079477. January 2015.
9 Based on internal test report #R0064457. Ex‐vivo Renal Burst Pressure report: "Verification ‐ Report ‐ LigaSure™ Renal Bench Burst Pressure Evaluation of the Valleylab™ FX8." May 3, 2015
10 Based on internal test report #RE00005503, Verification – report – GLP acute animal lab – LigaSure™ preclinical evaluation of Valleylab™ FX8. May 19, 2015.
11 Based on internal test report #RE00005401, Product validation of Valleylab™ FX8 surgeon and nurse evaluation in simulated use: 32 surgeons interviewed. January 27-30, 2015; Feb. 24-27, 2015.
12 Based on internal test report #R0064443 Rev A, Verification – report – ex vivo monopolar procedural flow evaluation on the Valleylab™ FX8 Orion. November 2014.
13 Based on internal test report #RE0064455, Autobipolar evaluation – Valleylab™ FX8. February 2015.
14 Based on the Valleylab™ FX8 User guide: part number 1073652. December 2014.
©2018 Medtronic. All Rights Reserved. 02/2018-US170997-[WF#1960968]
i